Tuesday, 25 May 2010
Following my post on the 28th April, I can now finally show my completed ArchiCAD model of my home so that I can measure exactly how many PVs we can fit on our roof.
(Thought I may as well show the rest of my lovely model too!)
As you can see from the highlighted areas on the Roof Plan and this Google Earth image of my house;
the roofs which would be suitable for the PVs are the S-S-E and the S-W facing roofs. The lightly highlighted area will only really be useful for Eastern morning sun so we'd prefer to not have any on that side however my mum wanted me to see how much area there is without this part so by using equations for the area of triangles and trapeziums, I calculated that;
The area of the S-S-E roof = 28.93 m^2
eliminating area of solar heating panels = 26.77 m^2
The area of the S-W roof = 32.51 m^2
eliminating area of Velux window = 30.34 m^2
Obviously the sizes of panels vary from supplier to supplier but as an example, the ones that we were looking at over the holidays were 900 mm x 1100 mm.
Note: the shading on the roof on the right hand side in December as early as 3p.m. - not suitable for getting the maximum use out of PVs.
Through modelling on ArchiCAD, I have worked out that it is in fact possible to fit 24 of the Hitachi Capitol panels (the ones which our little man came round to force upon us over the holidays).
However in my point of view he was quite rude and aggressive so we're most certainly going to be looking around a lot before actually purchasing them. In case anyone out these is keen in looking into the various companies in South-Wales to as far as Bristol-ish, these are some good websites which I plan to e-mail regarding offer quotes;
And one more really useful website for calculating the available sunlight for your home;
Have a go and see if you get roped in...!
Sunday, 2 May 2010
Update on the renovations...
Thought I'd post a few more pictures of the exciting renovations at No.27...
Lower: you can see straight through to the felt below the roof tiles!
As you can see at the moment there's only 50mm of polystyrene acting as insulation which would've be sufficient when it was renovated last - about 12 years ago - however other older parts of the upstairs don't even have this! And it was perfectly acceptable back then - weird.
So now we're going to put a relatively new kind of fabric-y insulation which to me looked like many layers of strong, silver foil separated by a thin layers of foam. It's very flexible so easy enough to staple to the existing structure and only about 2cm wide when its not being compressed. It has a U-value of 0.19 W/m2.K - it would take at least 100mm of a normal insulation board (such as a Kingspan one which we were going to have) to provide the same insulation!
Subscribe to:
Posts (Atom)